On many Gulf sites, cooling water is scarce, expensive to treat or simply not there. An air-cooled heat exchanger uses the ambient air instead. This guide explains when it is the better choice and how to design for the Gulf summer.
Water cooling needs a cooling tower or seawater system, chemical treatment, blowdown and make-up water. Air cooling needs only fans and power. It is usually the better choice when water is scarce, when the process outlet temperature can sit well above the hottest air temperature, or when the site is remote.
The hot process fluid flows through finned tubes in a bundle. Fans move air across the fins and carry the heat away. In a forced-draft cooler the fans sit below the bundle and push air up. In an induced-draft cooler they sit above and pull it through, which spreads the air more evenly and reduces hot-air recirculation. Air coolers for refineries and gas plants are built to API 661 (ISO 13706).
Send the fluid, flow, inlet and outlet temperatures, allowable pressure drop, design pressure and temperature, the site design air temperature and any noise limit. Each design is rated in HTRI before fabrication.
Our partner Spiro-Gills Thermal Products has built air coolers since 1946 for more than 100 countries.
Send it with your datasheet and we will reply.