02 · Air coolers · With Spiro-Gills, UK

Air-cooled condensers for steam and overhead vapours.

Condensers that turn steam or process vapour back into liquid using air, with sloped tubes so the condensate drains. Designed and built in Stafford by Spiro-Gills Thermal Products, supplied and supported in the GCC by Petromarsh.

SteamAnd overhead vapours
SlopedTubes drain condensate
No waterAir is the coolant
A-frame steam condenser · end viewSteam and condensateCooling air

Tap a part to see what it does. The red line is the steam flowing down the sloped tubes as it condenses, the blue lines are the air blown up by the fan and out through the bundles.

The basics

What an air-cooled condenser is, and how it works.

Vapour enters at the top and gives up its latent heat to air blowing across the fins. As it condenses, the liquid runs down sloped tubes to a condensate header. The design must drain liquid freely and remove gases that will not condense.

OVERHEAD

Process overhead condensers

Condense the vapour from the top of a distillation column, such as a crude or stabiliser column. Usually horizontal bundles with tubes sloped toward the outlet header, typically about 10 mm per metre.

STEAM

Steam condensing

Condense turbine exhaust or process steam, often under vacuum. A-frame bundles at a steep angle drain condensate and fit a large surface on a small plot.

VACUUM

Vacuum and gases

Under vacuum, air leaks in and any gas that will not condense blankets the tubes. A vent section and ejectors or vacuum pumps keep it moving out, so the surface stays active.

Why plants choose air-cooled condensers

  • No cooling water, so no water treatment, blowdown or seawater intake
  • Large surface on a small plot with A-frames
  • Fan speed control holds back pressure as ambient changes
  • No freeze protection needed in the Gulf

What to design for in the GCC

  • High design ambient: summer air at 45 to 50°C sets the size
  • Hot-air recirculation and wind around the fan deck
  • Sand and dust on the fins: plan for washing
Types

Condenser layouts and the duties they suit.

The right layout depends on whether you condense steam or process vapour, the pressure, and how much space you have. Tap a type to see when to use it.

A

A-frame steam condenser

Shown above

Two bundles lean together under a steam distribution header, with fans in the deck below. Condensate drains down the steep tubes to headers at the bottom.

Best for
Turbine exhaust and process steam
Pressure
Vacuum to low pressure

Used where water for a cooling tower is scarce or expensive.

Materials

Chosen for steam, condensate and hot air.

Steam condensers are mostly carbon steel with aluminium fins. Process overhead condensers follow the fluid, including sour and chloride-bearing vapours.

PartCarbon steelStainless and duplexOther options
Header boxesPlate, forgings and pipeSA-516 Gr 70 · SA-105 · SA-106 Gr B304L, 316L, duplex 2205SA-240 · SA-182 · SA-312Low-temperature carbon steel, impact testedSA-516 with SA-20 · SA-333 · SA-350 LF2
TubesSeamless or weldedSA-179 · SA-214 · SA-334304L, 316L, duplexSA-213 · SA-249 · SA-789Admiralty brass, copper-nickelSB-111
FinsAluminium, embedded or extruded, for long life1000-series aluminiumStainless welded fins for corrosive airwelded spiralGalvanised steel welded finshot-dip galvanised
Steam ductLarge-bore carbon steel duct and expansion joints, designed for vacuum and windwelded plate
Turbine exhaust steamCarbon steel tubes, aluminium fins, A-frame
Sour overhead vapourMaterials to NACE MR0175 / ISO 15156
Chlorides in overheadDuplex tubes, check dew point corrosion
High ambientMore surface and fan margin, not freeze protection
Standards

The codes we design, build and test to.

Process condensers follow API 661. Steam condensers for power use the same pressure codes and their own performance test code.

Air coolersAPI 661 / ISO 13706

Requirements for air-cooled heat exchangers in petroleum, petrochemical and natural gas plants: headers, tubes, fins, fans, drives and structure.

Pressure designASME VIII Div. 1

Pressure design of the header boxes, plugs and nozzles, with the U stamp where it is required.

Europe and UKPED 2014/68/EU

CE marking for Europe. UKCA under the Pressure Equipment (Safety) Regulations 2016 for the UK.

Thermal designHTRI Xace

Rating software from Heat Transfer Research, Inc. Not a code, but the industry reference for air-cooler thermal design.

Performance testASME PTC 30.1

Performance test code for air-cooled steam condensers.

Performance testASME PTC 30

Performance test code for air-cooled heat exchangers in general.

NoiseISO 3744 · ISO 9614

Sound power found from sound pressure (3744) or sound intensity (9614) measurements. Used to check the noise guarantee.

InspectionASME V · EN 10204 3.1

Non-destructive testing methods, and certified mill certificates for every pressure part.

Sour serviceNACE MR0175 / ISO 15156

Material and hardness limits for headers and tubes exposed to hydrogen sulphide.

How an order runs

From your enquiry to start-up, in ten steps.

Your engineers red-line our drawings, you approve the design twice before production starts, and you can witness the tests. Tap a step to see what happens and which documents you receive.

From Spiro-Gills, Stafford

Steam and overhead condensers from Stafford.

Spiro-Gills Thermal Products has designed and built bespoke air-cooled heat exchangers and finned tube in Stafford since 1946, and has supplied them to more than 100 countries. Thermal design is done in HTRI, welding is to ASTM code, and the company holds ISO 9001:2015. Petromarsh is their exclusive representative in the GCC.

Request a quote

Send the condensing duty.

For a condenser, the vapour, pressure and non-condensable gases matter most. The items on the right are enough to start the design.

  • Vapour composition, or steam
  • Flow rate
  • Operating pressure, including vacuum
  • Inlet temperature and degree of superheat
  • Non-condensable gas content
  • Required condensate outlet temperature or subcooling
  • Design ambient air temperature
  • Plot space and height limits
  • Noise limit
  • Site, delivery date and Incoterms