02 · Air coolers · With Spiro-Gills, UK

Re-tubing, replacement bundles and spares for air coolers.

We restore worn air coolers and upgrade them when the process has outgrown the original design. Re-tubing, bundles, finned tube and spare parts come from Spiro-Gills Thermal Products in Stafford, supplied and supported in the GCC by Petromarsh.

Re-tubeBundles restored
UpgradeFor higher duty
17+ yearsPetromarsh experience
Bundle lifted out for re-tubingReplaced tubesLift direction

Tap a part to see what it does. The red rows are the tubes being replaced, the blue arrows show the bundle being lifted out of the bay.

The basics

Repair, re-tube, replace or upgrade.

Air coolers wear from the inside, by corrosion and erosion of the tubes, and from the outside, by fin damage, fouling and drive wear. The right answer depends on what has failed and on what the process now needs.

RE-TUBE

Re-tube the bundle

Keep the headers and side frames, and replace some or all of the finned tubes. Often the best value when the headers are sound.

REPLACE

Replacement bundle

A new bundle built to fit the existing bay, nozzles and structure. The fastest way back to service, with the old bundle kept as a spare or scrapped.

UPGRADE

Upgrade for more duty

When throughput or ambient has grown beyond the original design, the HTRI design is rerun. More rows, better fins, a new tube material or bigger fans can restore the margin.

What service and spares give you

  • A bundle that fits the existing bay and pipework
  • Original or better performance after the shutdown
  • Spare plugs, gaskets and fan parts on the shelf
  • A record of what was done for your maintenance history

Signs a cooler needs attention

  • Outlet temperature high in summer, or fans at full speed all year
  • Leaking plugs or tubes, or many tubes already plugged
  • Damaged, loose or corroded fins, or frequent fan trips
Services

What we can do for an existing cooler.

Spiro-Gills can work from the original drawings, or measure the old bundle where none exist. Tap a service to see what it covers.

RT

Re-tubing

Most common

Damaged tubes are removed and new finned tubes fitted into the existing headers. A full re-tube restores the bundle, and new fin types can be fitted at the same time.

Best for
Sound headers, worn tubes
Includes
Hydrotest and new plugs and gaskets
Materials

Repairs in the right material.

Replacement parts are made from the original materials, or from better ones where the old material has failed.

PartCarbon steelStainless and duplexOther options
Header boxesPlate, forgings and pipeSA-516 Gr 70 · SA-105 · SA-106 Gr B304L, 316L, duplex 2205SA-240 · SA-182 · SA-312Low-temperature carbon steel, impact testedSA-516 with SA-20 · SA-333 · SA-350 LF2
TubesSeamless or weldedSA-179 · SA-214 · SA-334304L, 316L, duplexSA-213 · SA-249 · SA-789Admiralty brass, copper-nickelSB-111
FinsAluminium, the usual choice1000-series aluminium stripStainless steel welded finsfor hot or corrosive airCopper fins, or galvanised carbon steel welded finshot-dip galvanised
Plugs and gasketsShoulder plugs in carbon or stainless steel, with soft iron, aluminium, copper or stainless gaskets matched to the header materialSA-105 · SA-182
Tubes corroded insideUpgrade tube material, e.g. stainless or duplex
Fins corroded or looseRe-tube with extruded or embedded fins
Plug leaksNew plugs and gaskets, check thread condition
Lost duty in summerUpgrade study before re-tubing like for like
Standards

The codes repairs are made and tested to.

Repairs follow the code the cooler was built to, plus the inspection rules your site uses.

Air coolersAPI 661 / ISO 13706

Requirements for air-cooled heat exchangers in petroleum, petrochemical and natural gas plants: headers, tubes, fins, fans, drives and structure.

Pressure designASME VIII Div. 1

Pressure design of the header boxes, plugs and nozzles, with the U stamp where it is required.

In-service inspectionAPI 510 · API 572

Inspection of pressure equipment in service, used by many sites for coolers and their headers.

RepairsASME PCC-2

Repair methods for pressure equipment and piping.

Fitness for serviceAPI 579-1 / ASME FFS-1

Assessing whether worn or damaged equipment can stay in service.

Thermal designHTRI Xace

Rating software from Heat Transfer Research, Inc. Not a code, but the industry reference for air-cooler thermal design.

Materials and weldingASME II · ASME IX

Material specifications, and qualified welding procedures and welders for headers and tube-to-tubesheet joints.

InspectionASME V · EN 10204 3.1

Non-destructive testing methods, and certified mill certificates for every pressure part.

Europe and UKPED 2014/68/EU

CE marking for Europe. UKCA under the Pressure Equipment (Safety) Regulations 2016 for the UK.

How an order runs

From your enquiry to start-up, in ten steps.

Your engineers red-line our drawings, you approve the design twice before production starts, and you can witness the tests. Tap a step to see what happens and which documents you receive.

From Spiro-Gills, Stafford

Re-tubing and spares from Stafford.

Spiro-Gills Thermal Products has designed and built bespoke air-cooled heat exchangers and finned tube in Stafford since 1946, and has supplied them to more than 100 countries. Thermal design is done in HTRI, welding is to ASTM code, and the company holds ISO 9001:2015. Petromarsh is their exclusive representative in the GCC.

Request a quote

Send the nameplate and the problem.

Old drawings and photos help most. If you have none, the items on the right are enough to start, and the bundle can be measured.

  • Cooler nameplate and tag number
  • Original datasheet and drawings, if any
  • Photos of the bundle, headers and fans
  • What has failed, and how often
  • Number of tubes already plugged
  • Current flow and temperatures
  • Planned shutdown date
  • Parts needed: plugs, gaskets, fan parts, tube
  • Repair, replace or upgrade preference
  • Site and Incoterms